Products - Marx Generator - MG20-22C-2000PF


Big Unit Megavolt Marx Generator System
MG20-22C-2000PF
1.1 kJ 1MV
KEY PARAMETERS
• Maximum open circuit voltage: 1 MV
• Peak voltage into matched load: 500 kV
• Maximum repetition rate: 20 Hz
• Energy per pulse: 1.1 kJ

APELC MG20-22C-2000PF
General Specifications
SymbolParameterValueUnits
L Length 1.52 m
D Diameter 50 cm
Wt Total Weight 45.4 kg
N Number of Stages 20 -
Ve Erected Voltage 1000 kV
Vch Maximum Charge Voltage 50 kV
Pmax Maximum Peak Power (matched load) >12 GW
Cstage Capacitance Per Stage 44 nF
Ce Erected Capacitance 2.2 nF
Zsource Source Impedance 18 Ohms
TECHNOLOGY SUMMARY

The APELC MG20-22C-2000PF is a mega-volt class Marx generator specifically designed to drive low impedance loads. With a 50 kV charge voltage and an 18 Ohm source impedance, this generator will deliver a 500 kV, 1.1kJ pulse into a matched load, with a peak power of more than 12 GW. This generator brings patent-pending low impedance, parallel-switched topology, which makes it well suited for a wide variety of High Power Microwave loads.

 
Charging elements type Resistive
Output capabilities Vacuum interface and resistive dummy load
 
system1_devices

APELC Pressurized load module designed for output integration with the Big Unit Megavolt Marx Generator.

system1_devices

Load voltage waveform a matched load and Marx charge voltage of 40 kV.

system1_devices

Ring down waveform of the Big Unit Megavolt Marx Generator: a short circuit discharge terminated into a CVR module.


SUGGESTED PERIPHERALS
APELC High Voltage Trigger Unit
Inline, coaxial Current Viewing Resistor
APELC Integrated Rapid Capacitor Charging Power Supply
APELC integrated pressurized load module
 
SYSTEM REQUIREMENTS
0 - 50 kV dc charge voltage
200 psi dry air source
Suitable high voltage trigger source