MIL-STD 188-125 E2 Intermediate Pulse Test System

APELC’s MIL-STD 188-125 E2 Test System is designed to meet the E2 or intermediate pulse specifications for direct injection testing according to the MIl-STD 188-125 HEMP facility test system. The test system is portable and battery operated for use on remote or mobile platform test subjects. 

SPECIFICATION VALUE
Peak current 250A
Risetime 1.5 µs
Pulse Width 3-5 ms
Size: 19.7” x 24.6” x 11.7” (50cm x 62.5cm x 29.7cm)
Weight: < 44 lbs (20 kG)
Accessories : Dummy Load, test cables, certified couplers.

inter-pulse1

inter-pulse2