MG-15-3C-940PF-HRR-SYS
6.5 kJ/s 33 J/pulse 600 kV


Key Parameters
• Maximum open circuit voltage: 600 kV
• Peak voltage into matched load: 300 kV
• Maximum repetition rate: 200 Hz
• Energy per pulse: 33 kJ
• Pulse risetime: < 1 ns

APELC MG-15-3C-940PF-HRR-SYS General Specifications
Symbol Parameter Value Units
N
Number of Generator Stages
15
-
Epulse
Maximum Marx Energy per pulse
33.0
J
-
Maximum vessel pressure
150
PSI
Vch
Marx Peak Charge Voltage
40
kV
Ve
Peak Erected Voltage
600
kV
Cstage
Capacitance Per Marx Stage
2.8
nF
Ce
Erected Capacitance
188
pF
Le
Erected Inductance
510
nH
Zm
Marx Impedance
52
ohm
L
Length
31
in
D
Diameter
6
in
RRmax
Max Burst-Mode Repetition Rate
200
Hz
Technology Summary
The APELC MG15-3C-940PF-HRR-SYS is a fully-integrated turnkey pulse-power system based on our 15-stage generator designed for compact, high power RF applications. This generator is characterized by a sub-ns risetime and GW peak power levels. The generator is matched with the APELC Trigger Unit (HRR-TU-18kV-500Hz), a Lambda ALE 802L High Voltage Power Supply, and a Berkeley Nucleonics 575 Delay generator.
The APELC HRR-TU-18kV trigger unit utilizes a thyratron-based pulse forming circuit to provide the trigger pulse to the Marx generator. The unit also conditions and routes optical signals from the delay generator to control the charge and inhibit cycles of the thyratron HVPS and the Marx HVPS. This functionality allows pulse charging of both the thyratron and the Marx generator. The pulse charging mode of operation minimizes high voltage DC degrading effects (e.g. corona) and provides a safer high voltage environment since the default state of all power supplies is inhibited.
The MG15-3C-940PF-HRR-SYS integrated system includes all cabling and accessory items needed for interconnect. Custom load modules and integrated diagnostics can be tailored for your system needs. All you need to operate this high-repletion-rate pulsed power source is a pressurized air source and a wall outlet.

MG-15-3C-940PF-HRR system with major components indicated: (A) Marx high voltage power supply, (B) fiber-optic delay generator, (C) pulse generator trigger unit, (D) MG 15 series Marx generator, (E) trigger unit data cable, (F) trigger unit output cable, (G) fiber-optic cable assembly, (H) Marx HVPS output cable.


Load voltage waveform of the MG20-1C-100NF Generator into a 50-Ω cable load.

Screen Capture of analog charge diagnostics for a 200 Hz Burst:
Thyratron charge waveform (blue) and Marx Charge waveform (red).


Suggested Peripherals
System Requirements
Contact APELC

APELC High Repetition Rate Trigger Unit HRR-TU-18kV-500Hz
3-phase prime power source
Phone: 512.264.1804
Berkeley Nucleonics 575 Delay Generator
200 psi dry air source
Fax: 512.264.1784
APELC integrated pressurized load module
Lambda ALE 802L High Voltage Power Supply